dc.contributor.authorWardak, Cecylia-
dc.contributor.authorPietrzak, Karolina-
dc.date.accessioned2024-12-02T10:42:58Z-
dc.date.available2024-12-02T10:42:58Z-
dc.date.issued2019-
dc.identifier.citationModern problems and solutions in environmental protection. Post-conference monograph of Current Environmental Issues 2019, edited by Joanna Karpińska, Marek Bartoszewicz, Róża Sawczuk, Białystok 2019, s. 110-114pl
dc.identifier.isbn978-83-7431-601-9-
dc.identifier.urihttp://hdl.handle.net/11320/17675-
dc.description.abstractCheap and simple, an all solid state lead ion selective electrode for lead determination is described. The PVC electrode membrane was modified by addition of multiwalled carbon nanotubes and ionic liquid 1-hexyl-3-methylimidazolium hexafluorophosphate. The electrode with a modified membrane was characterized by a lower detection limit and better selectivity in relation to sodium, potassium, and calcium ions than an electrode having membrane with a classic composition. It also exhibited good potential stability and reprodUcibility.pl
dc.language.isoenpl
dc.publisherUniversity of Bialystok Presspl
dc.subjectlead ion-selective electrodepl
dc.subjectsolid contactpl
dc.subjectionic liquidpl
dc.subjectmultiwalled carbon nanotubespl
dc.titleAn all solid state ion-selective electrode for lead monitoring in the environmentpl
dc.typeBook chapterpl
dc.rights.holder© Copyright by Uniwersytet w Białymstoku, Białystok 2019pl
dc.description.AffiliationCecylia Wardak - Department of Analytical Chemistry and Instrumental Analysis, Faculty of Chemistry, Maria Curie-Sklodowska Universitypl
dc.description.AffiliationKarolina Pietrzak - Department of Analytical Chemistry and Instrumental Analysis, Faculty of Chemistry, Maria Curie-Sklodowska Universitypl
dc.description.referencesManahan, S. E. Toksykologia środowiska. Aspekty chemiczne i biochemiczne. 1st edn. Warsaw, Wydawnictwo Naukowe PWN, 2010: 168 pp.pl
dc.description.referencesNaumczyk J., Chemia środowiska, 1st edn. Warsaw, Wydawnictwo Naukowe PWN, 2017: 191 pp.pl
dc.description.referencesBobacka J. (2006) Conducting polymer-based solid-state ion-selective electrodes. Electroanalysis, 18: 7-18.pl
dc.description.referencesPaczosa-Bator B., Cabaj L., Piech R., Skupien K. (2012) Platinum nanoparticles intermediate layer in solid-state selective electrodes. Analyst, 137: 5272-5277.pl
dc.description.referencesGrygolowicz-Pawlak E., Plachecka K., Brzózka Z., Malinowska E. (2007) Further studies on the role of redox-active monolayer as intermediate phase of solidstate sensors. Sensor and Actuators B-Chem., 123: 480-487.pl
dc.description.referencesPing J., Wang Y, Wu J., Ying Y (2011) Development of an all-solid-state potassium ion-selective electrode using graphene as the solid-contact transducer. Electrochemical Communications, 13: 1529-1532.pl
dc.description.referencesBakker E., Pretsch E., Bühlman P. (2000) Selectivity of potentiometric ion sensors. Analytical Chemistry, 72: 1127-1133.pl
dc.description.firstpage110pl
dc.description.lastpage114pl
dc.identifier.citation2Modern problems and solutions in environmental protection. Post-conference monograph of Current Environmental Issues 2019, edited by Joanna Karpińska, Marek Bartoszewicz, Róża Sawczukpl
dc.conferenceXIV Międzynarodowa Interdyscyplinarna Konferencja „Current Environmental Issues – 2019”, Białystok 24-26 września 2019 r.pl
Występuje w kolekcji(ach):Książki / Rozdziały (WUwB)
XIV Międzynarodowa Interdyscyplinarna Konferencja "Current Environmental Issues-2019", 24-26 września 2019

Pliki w tej pozycji:
Plik Opis RozmiarFormat 
C_Wardak_K_Pietrzak_An_all_solid_state_ion_selective_electrode.pdf1,17 MBAdobe PDFOtwórz
Pokaż uproszczony widok rekordu Zobacz statystyki


Pozycja jest chroniona prawem autorskim (Copyright © Wszelkie prawa zastrzeżone)